Design for testing 3 phase protection relays, Energy Meter & Transducer; Laptop PC or PDA control; 6 current & 4 voltage output; Other models of different current & voltage are also available.
Microprocessor controlled with phase angle shifter and frequency generator; Design for testing relays and transducers; High power outputs; Oscilloscope function of current and voltage.
Built in digital time display contact time in cycles & milli seconds; Provides variable AC current source up to 250A; Back- lit LCD screen; Provides variable AC voltage source up to 250V; Provides variable DC voltage source up to 300V; Auxiliary AC/DC power supplies 24Vdc, 124Vdc and 240Vdc; Test current transform excitation;
CT excitation, ratio and polarity test; Primary injection testing capabilities; 3000V AC Hipot Testing; Generation up to 800Amps; Test results & setting are saved into local memory.
Saturation test using the ANSI/IEEE C57.13.1; Voltage range from 50,300,500,1200 and 2000 Vac; Polarity test and CT ratio test range from 0.8 to 5000; CT Winding resistance from 100 micro-ohm to 10 ohms; CT burden test by injecting 1A or 5A test current; Built in 2.5 inch wide thermal printer; Computer interface via RS232C or USB port;
Circuit breaker timing test set; Up to 2 break per pole; Static and dynamic contact resistance measurement; Built in 200A Micrometer & Battery Operation; Motion and speed analyzer.
Built in 200A microhmmeter; 12 Auxiliary timing input; Analysis & Result evaluation directly on the display; 18 main and 18 resistive contact input; Motion & Speed analyzer.
Quick shot mode for on-line timing, Capture first trip time; Static and dynamic contact resistance measurement; Detects main contact and insertion-resistor contact on same input channel; Prints breaker analysis results in both tabular and graphic format. Supports resistance type transducer
Automatic testing; Voltage can be selected from 1KVdc to 80KVdc in steps of 1KVdc; Built in 2.5 inch thermal printer; Reliable and lightweight; Can stores up to 84 test records of 16 readings; Computer interface via RS232C or USB port;
High current output up to 7000A; Powerful output up to 35KVA; Modular design for easy transport; Protections relay test; Low voltage breaker testing; Heat run test & CT testing;
Primary Injection testing capabilities; Generates up to 800A (Optional up to 4000A); 3000V AC Hipot Testing; Test result and settings are saved into local memory; Large graphical display.
Ruggedly constructed for field use; High current output with appropriate controls & instrumentation; Output up to 1000A, 5V; Overload: 5000Amps; Short duration overloads are possible on each taps
Test protection system; Test the time delay characteristics of protection relays and MCCB; Measure internal and external circuit; Provide thermal protection;
Third harmonic analysis of leakage current with compensation; Online diagnostics of metal oxide surge arrestors; According to IEC60099-5A1 “diagnostics indicators of metal oxide surge arrestors in service”;
Outstanding imaging and temperature measurement; Measurement Range: 0° C to + 250° C; Field of view (FOV): 20°x15°; Zooming facility available; Hot and cold spot detection; Battery operated.
Outstanding imaging and temperature measurement performance; Suitable for high temperature measurement; Imaging Range: +50° C to + 900° C; Field of view (FOV): 20°x15°; Detection: 160 X 120 pixels; Colour LCD with LED backlight; Battery operated.
Audio out for headset or Pc recording; 7 segment display in relative dB mode; 90 dB dynamic range display; Center frequency range 40 KHz; Bandwith38KHz to 48 KHz; 4 hour autonomy; Integrated display.
HV and MV SF6 Circuit Breakers Current and Voltage Transformer High Voltage Surge Arrestors (MOV’s)
The most accurate overhead transmission and distribution line fault locator; Accuracy: ± 150m typical, regardless the line length; Time synchronization with accuracy of ± 1 µs; Unaffected by fault resistance; Suitable for all kind of power lines AC and DC; Automatic distance to fault calculation; Unlimited number of monitored lines; Reduce overhead lines outage time; Non intrusive installation; Easy to set up;